Rates

Units can review their current off-campus connections charges in the Online Service Center in the Summary of Charges report.

Fiber

The following lease rates apply to “dark fiber” access. Note: these rates do not include any other costs associated with connectivity to the University Network, such as Engineering, Materials, and Labor, etc.

Item Billing Code Monthly Charge Activation Charge
Fiber Strand FM-FIBER $0.01/foot Time and Materials
Note: Fiber is designed and installed in buildings without current connections on a time and materials basis. Your ITS Infrastructure Project Manager can prepare an estimate of the work required.

Fixed Wireless

Description Speed Distance Device Code Billing Code Monthly Charge
Fast Ethernet 100 Mbps Up to 1 mile FE60U DC-100M-FW5 $479.50
Gigabit Ethernet 100/1000 Mbps Up to 1 mile AR60 DC-1000M-FW5 $640.30
Fast Ethernet 100 Mbps Up to 5 miles FE80U DC-100LR-FW5 $681.15

Note: Fixed wireless is designed and installed on a time & materials basis. Labor and materials costs to install the two fixed wireless radios include:

  • Installations
  • Installed fiber and power cables
  • Labor for engineering, installation, and testing

Labor and materials costs to install the networking components and power protection at the off campus location include:

  • Ethernet switches
  • Phones
  • WiFi (Wireless Access Points)
  • Uninterrupted Power Supply Units, if appropriate

Your ITS Infrastructure Project Manager can prepare an estimate of the work required.

DS-1 & DS-3

Service Installation Billing Code One-Time Charge Utilization Billing Code Monthly Rate
Off campus T1, DS-1, or PRI circuit that requires extension to some point on campus and requires NO line conditioning equipment and is not terminated on the MSL-100. External Carrier costs are directly passed through to the end user. ITCom recurring costs include cable plant, cable plant maintenance, and record keeping. IN-T1EXTNT $450.00
Off campus T1, DS-1, or PRI circuit that requires extension to some point on campus and requires line conditioning equipment. External Carrier costs are directly passed through to the end user. ITCom recurring costs include circuit maintenance and record keeping. IN-T1EXT $450.00 LN-T1EXT $126.85
On campus customer T1, DS-1, or PRI circuit that DOES terminate on the SL-100. IN-T1INTSW $1,200.00 LN-T1INTSW $444.30
On campus customer T1 point to point circuit that does not terminate on the SL-100. IN-T1PTP $720.00 LN-T1PTP $114.60
SL-100 ISDN 128K 2B+D (Non-Backbone). IN-ISDN $200.00 LN-ISDN $30.25

Copper Circuits

Service Installation Billing Code One-Time Charge Utilization Billing Code Monthly Rate
Intra-Building 2 Wire: Copper wire circuit within the building Time and Materials
Intra-Building 4 Wire: Copper wire circuit within the building Time and Materials
Circuit routed out of building, 2 Wire: Dry Copper Pair Time and Materials DC-CO2W $1.45
Circuit routed out of building, 4 Wire: 2 Dry Copper Pair Time and Materials DC-CO4W $2.90
Note: DS-1 and DS-3 connections are generally being phased out as an off-campus connection option going forward. Your ITS Infrastructure Project Manager can work with network engineers to determine if this would be an appropriate connection in the future or if you’d like to transition an older DS-1 or DS-3 connection to one of the other options.